- Bushing Type Current Transformers
- 2017-12-30 23:40
- LZCT Bushing Type Current Transformer is suitable for current measurement, metering and microcomputer protection of distribution equipments in 35kV and 10kV AC power system. It iswidely used in compact fully insulated ring main unit and Reactive compensat
- MV Reactive Power Compensation
- 2017-12-30 10:06
- The basic principle of reactive power compensation is to parallel capacitive power load device with inductive power load in the same circuit, so that the energy can interchange between the two loads. Thus the reactive power required by inductive load coul
- 24 kV Current Transformers
- 2017-12-09 09:08
- LDZC-24 high precision current transformer is suitable for current measurement and protection of distribution equipments in 24kV AC power system. It is widely used in compact fully insulated ring main unit such as Safe Ring/Safe Plus, RM6/SM6, SVS, GA/GE,
- Zero Sequence Current Transformers
- 2017-11-29 14:56
- LXZ zero sequence current transformer is suitable for use in 10kV power system of three-phase zero sequence current detection and single-phase grounding protection. When it is used in the line switches for single phase ground protection, there is Watch DO
- Combined Current And Voltage Transformers
- 2017-11-21 02:47
- JLSZ-10 Combined Instrument Transformer Brief introduction The current and voltage combined type instrument transformer is used in power system of 50Hz or 60 Hz rated frequency, 1KV and below rated voltage, for energy measurement. Type designation Technic
- Outdoor Current Transformers
- 2017-11-13 11:44
- Technical data: ● The product performance is in accordance with GB1208 and IEC60044-1 standards ● Rated insulation level 40.5/95/185 kV ● Rated frequency 50Hz or 60Hz ● Rated secondary current 5A or 1A ● Ambient temperature –25℃~+40℃ ● Altitude:Up to 1000
- Distribution Automation Data Transfer Units
- 2017-11-12 01:09
- PSW300 series intelligent power distribution terminal (DTU) is the latest development of the company's new generation watchdog controller according to integrated domestic and foreign advanced technology, the actual demand of the power distribution area. T
- Ring Type Current Transformers
- 2017-10-27 22:39
- LMZ1-0.66, LMZ1-0.5, LMZ(J) 1-0.5 Series indoor, fully sealed, casting type low voltage CT is busbar type casting insulation indoor type products,Applied to ac 50hz, 500 v and below circuit, current, power, and in the power measurement and relay protectio
- Indoor Voltage Transformers
- 2017-10-24 11:18
- Technical data:· The product performance is in accordance with GB1207 and IEC60044-2 standards · Rated insulation level 3.6/20/45 kV· Rated frequency 50Hz or 60Hz· Ambient temperature –25℃~+40℃· Altitude: Up to 1000m above sea level· Indoor device...
- CT Powered Feeder Protection Device
- 2017-10-22 10:52
- PSW101 universal CT powered protection device is a 10KV feeder protection device which has the function of over current, fast breaking protection and grounding protection according to the use of domestic users. With the use of standard current transformer
- Overhead Fault Indicators
- 2017-10-08 03:23
- This product series are suitable for aerial lines. SFI-W5 has the functions of real-time operating status computer display and sending fault description information to the mobile phone of management staff according to the regulations. Faults indicate: whi
- 35 kV Current Transformers
- 2017-10-02 00:29
- LDZC-35 high precision current transformer is suitable for current measurement and protection of distribution equipments in 35kV AC power system. It is widely used in compact fully insulated ring main unit such as Safe Ring/Safe Plus, RM6/SM6, SVS, GA/GE,
- Outdoor Split Core Current Transformers
- 2017-09-29 23:18
- LZKW-10ǁ Outdoor Split Core Current Transformer is line automatic reactive compensation in special equipment, its outstanding characteristic is installed, not need truncation wires can be charged installation. The outside of the silicone rubber cover, inc
- LV Reactive Power Compensation
- 2017-08-05 10:15
- Low Voltage Reactive Power Compensation Unitserie is an integrated power distribution product gathering the functions of power distribution, measurement, protection, control and compensation, which installed at the low-voltage side of the transformers. It
- Outdoor Voltage Transformers
- 2017-08-03 15:37
- Technical data:· The product performance is in accordance with GB1207 and IEC60044-2 standards · Rated insulation level 12/42/75 kV· Rated frequency 50Hz or 60Hz· Ambient temperature –25℃~+40℃· Altitude: Up to 1000m above sea level· Outdoor device...
- Rectangular Current Transformers
- 2017-08-03 15:29
- BH-0.66、LMK2-0.66I Series of Low voltage current transformer is mainly used for indoor, For the rated voltage of 0.66kV and below, Rated frequency 50 Hz AC circuit, As the current electric energy measurement and relay protection .The product is a new shel
- 10 kV Current Transformers
- 2017-07-23 17:55
- LDZC-10 high precision current transformer is suitable for current measurement and protection of distribution equipments in 10kV AC power system. It is widely used in compact fully insulated ring main unit such as Safe Ring/Safe Plus, RM6/SM6, SVS, GA/GE,
- Indoor Current Transformers
- 2017-07-07 06:44
- · The product performance is in accordance with GB1208 and IEC60044-1 standards· Rated insulation level 12/42/75 kV· Rated frequency 50Hz or 60Hz· Rated secondary current 5A or 1A· Ambient temperature –25℃~40℃· Altitude: Up to 1000m above sea level · Indo
- Overhead 2-Remotes Fault Detection System
- 2017-07-06 06:02
- Hyliton Power Technology is one of the largest and experienced manufacturers and suppliers of high-tech products in China who can offer you advanced and high quality overhead 2-remotes fault detection system OEM at competitive price. Welcome to order our
- W Type Current Transformers
- 2017-07-04 04:01
- General description: W type for the current transformer is SEG company WIC1 type self-supply protection device of special current transformer can provide for WIC1 measuring current and work power. Test winds can be directly verified protect windings setti